2600
Crossmatch (Flow Cytometry)
Order Code: 2600
Get Requisition Form
Test Information
The flow cytometric lymphocyte crossmatch is a technique for evaluating the compatibility of potential transplant recipients and donors and analyzed for the presence of bound IgG antibodies.
Disease State
Solid Organ Transplantation
Test Type
Functional/Serologic Test
Sample Notes
Clot Tube (red top) and ACD Solution B preferred on recipient. If ACD solution B not available, Sodium Heparin Whole Blood is acceptable on recipient.
Requested Volume
One 10 ml Clot Tube (red top) and 40 ml ACDB (yellow top) on recipient
Minimum / Pediatric Volume
One 5 ml Clot Tube (red top) and 20 ml ACDB (yellow top) on recipient
Additional Sample Information
Sodium Heparin Whole Blood is acceptable if received within 24 hours on recipient.
Shipping Information
Room Temperature
CPT Codes
- 86825 (first serum/dilution)
- 86826 (each addtl serum/dilution)
Method
Flow Cytometry
Turnaround Time
7 days
New York State Approval
Yes
DEX Z-Code™
No