Crossmatch (Flow Cytometry) Against Recipient
Order Code: 2610
Get Requisition Form
Test Information
Recipient serum is incubated with donor lymphocytes which are analyzed in a flow cytometer for the presence of bound IgG antibodies to find donor-specific antibodies to avoid deleterious graft function.
Disease State
Solid Organ Transplantation
Test Type
Functional/Serologic Test
Sample Notes
Clot Tube (red top) on recipient and ACDB (yellow top) on donor is preferred. If ACDB is not available, Sodium Heparin whole blood is acceptable.
Requested Volume
One 10 ml Clot Tube (red top) on recipient and 40 ml ACDB (yellow top) on donor
Minimum / Pediatric Volume
One 5 ml Clot Tube (red top) on recipient and 20 ml ACDB (yellow top) on donor
Additional Sample Information
Sodium Heparin whole blood is acceptable if received on donor within 24 hours of draw.
Shipping Information
Room Temperature
Method
Flow Cytometry
Turnaround Time
7 days
DEX Z-Code™
No